In-row & Precision Cooling

AquaRow CW In-row Chilled Water

Central plant efficiency, row-level control.

A chilled-water in-row unit for facilities that already run a central chiller plant. 35–120 kW of sensible capacity in a 300 mm frame, with EC fans and condensate-free operation.

120 kW Max. capacity
300 mm Frame width
0 dB Compressor noise
N+1 Fan redundancy
AquaRow CW In-row Chilled Water — 35–120 kW chilled-water cooling for large halls

Overview

Why this system exists

Where a chiller plant already exists, extending it into the row is the lowest-carbon option. The AquaRow CW connects to the building loop and delivers 35–120 kW of sensible cooling inside the aisle, with a motorised three-way valve and EC fans that modulate to the actual rack load.

Because there is no compressor in the row, service access is simpler and the unit runs quietly. A 6-row N+1 layout is typical for a 1 MW hall, and each unit can be isolated without affecting its neighbours.

Positioning. 35–120 kW chilled-water cooling for large halls. Configurations are built to order — capacity, redundancy, enclosure rating and monitoring can be specified for your site.

Engineering

Key features

Every item below is verifiable in the datasheet or on the factory acceptance test record.

35–120 kW sensible capacity
No compressor — quiet, low-maintenance operation
Motorised 3-way valve with 0–100% modulation
EC fans with N+1 redundancy
Coil designed for 12/18 °C or 15/21 °C chilled water
Isolating valves for unit-level maintenance

Data

Specifications

Typical values for the standard configuration. Site-specific schedules are issued with the quotation.

Cooling specifications
Sensible capacity35 – 120 kW
Airflow3 000 – 9 000 m³/h
Water flow1.6 – 5.7 l/s
Pressure drop< 45 kPa

Deployment

Typical applications

Hyperscale and colocation halls with central chillers District-cooling connected facilities Large enterprise data centers Halls with strict acoustic requirements

Not on the list? These systems are also deployed in broadcast, rail signalling, laboratory and defence facilities — send us your environment and we will confirm suitability.

Documentation

Datasheets & manuals

The technical datasheet, installation manual and declaration of conformity for this product line are available in the download library. Drawings in DWG and PDF are issued with the quotation.

Open download library Ask for a drawing

Next step

Get this system sized for your site.

Share your rack count, density and redundancy target. We reply with a configuration, drawings and a budgetary price.