HatchPower HP33-L Lithium UPS
More runtime. Less floor. Full visibility.
The HP33 platform paired with LFP battery cabinets and an integrated BMS. Same 97.6% efficiency, but a footprint and weight that fit a retrofit where lead-acid never could.
Overview
Why this system exists
Lithium iron phosphate (LFP) cells change the economics of UPS batteries: roughly 40% of the volume and 60% of the weight of an equivalent VRLA bank, a ten-year design life, and a BMS that reports cell-level state of health long before a string fails.
The HP33-L ships as a matched pair — UPS frame and battery cabinet — with the BMS communicating directly to the UPS controller over CAN. Runtime is calculated from live cell data rather than a fixed voltage curve, so the number on the HMI is the number you actually have.
Engineering
Key features
Every item below is verifiable in the datasheet or on the factory acceptance test record.
Data
Specifications
Typical values for the standard configuration. Site-specific schedules are issued with the quotation.
| Rated power | 50 – 600 kVA |
|---|
| Chemistry | Lithium iron phosphate (LFP) |
|---|---|
| Design life | 10 years at 25 °C |
| Cycles | > 4000 at 80% DoD |
| Monitoring | Cell-level voltage and temperature via BMS |
| Footprint saving | ≈ 40% vs equivalent VRLA bank |
|---|
| BMS link | CAN 2.0B to UPS controller |
|---|
| Standards | IEC 62619, UN 38.3, IEC 62040-1 |
|---|
Deployment
Typical applications
Not on the list? These systems are also deployed in broadcast, rail signalling, laboratory and defence facilities — send us your environment and we will confirm suitability.
Documentation
Datasheets & manuals
The technical datasheet, installation manual and declaration of conformity for this product line are available in the download library. Drawings in DWG and PDF are issued with the quotation.
Related systems
Often specified together
HatchPower HP33 Modular UPS
A hot-swappable modular UPS platform that grows in 50 kVA steps, keeps critical loads on double conversion at 97.6% efficiency and allows zero-downtime maintenance from the front of the cabinet.
HatchPower HP11 Tower UPS
A compact tower UPS for small server rooms, branch offices and telecom cabinets. Online double conversion in a 2U–4U footprint with a maintenance bypass built in.
AquaRow IRC In-row DX Cooling
Row-mounted DX units that sit inside the aisle they cool, delivering 25–60 kW of sensible capacity with EC compressors, variable-speed fans and optional free cooling.
Next step
Get this system sized for your site.
Share your rack count, density and redundancy target. We reply with a configuration, drawings and a budgetary price.