In-row & Precision Cooling
AquaRow IRC In-row DX Cooling
Cooling placed where the heat actually is.
Row-mounted DX units that sit inside the aisle they cool, delivering 25–60 kW of sensible capacity with EC compressors, variable-speed fans and optional free cooling.
Overview
Why this system exists
Room-level CRAC units cool a volume. In-row units cool a rack. Placed between two racks in a hot aisle, an IRC unit draws hot air directly from the exhaust stream and returns cold air to the cold aisle at a distance measured in centimetres — which is why it can handle 25–60 kW from a single 300 mm frame without over-pressurising the floor.
Capacity modulates continuously: inverter compressors and EC fans follow the actual IT load rather than cycling on and off. In cool climates the free-cooling coil takes over whenever the outdoor temperature allows, and the unit reports coil, compressor and airflow data to the DCIM platform.
Engineering
Key features
Every item below is verifiable in the datasheet or on the factory acceptance test record.
Data
Specifications
Typical values for the standard configuration. Site-specific schedules are issued with the quotation.
| Sensible capacity | 25 / 35 / 45 / 60 kW |
|---|---|
| Airflow | 2 500 – 6 500 m³/h |
| Compressor | Inverter scroll, 10–100% modulation |
| Refrigerant | R410A / R32 (low-GWP option) |
| Free cooling | Optional coil with modulating valve |
| Power supply | 380–415 V AC 3Ph, 50/60 Hz |
|---|
| Dimensions | 300 × 1100 × 2000 mm (W×D×H) |
|---|---|
| Weight | ≈ 290 kg |
| Filtration | G4 standard, F5 optional |
|---|
| Protocols | Modbus RTU/TCP, SNMP, BACnet gateway |
|---|
| Operating range | -20 to 45 °C outdoor (condenser) |
|---|
Deployment
Typical applications
Not on the list? These systems are also deployed in broadcast, rail signalling, laboratory and defence facilities — send us your environment and we will confirm suitability.
Documentation
Datasheets & manuals
The technical datasheet, installation manual and declaration of conformity for this product line are available in the download library. Drawings in DWG and PDF are issued with the quotation.
Related systems
Often specified together
HatchPower HP33 Modular UPS
A hot-swappable modular UPS platform that grows in 50 kVA steps, keeps critical loads on double conversion at 97.6% efficiency and allows zero-downtime maintenance from the front of the cabinet.
HatchPower HP11 Tower UPS
A compact tower UPS for small server rooms, branch offices and telecom cabinets. Online double conversion in a 2U–4U footprint with a maintenance bypass built in.
HatchPower HP33-L Lithium UPS
The HP33 platform paired with LFP battery cabinets and an integrated BMS. Same 97.6% efficiency, but a footprint and weight that fit a retrofit where lead-acid never could.
Next step
Get this system sized for your site.
Share your rack count, density and redundancy target. We reply with a configuration, drawings and a budgetary price.