Containerized Data Centers
CubeDC 20 ft IT Pod
A data hall that fits on a flatbed.
A factory-built 20 ft IT container with 8–12 racks, in-row cooling, UPS and fire suppression. ISO footprint, standard twist locks, shipped anywhere.
Overview
Why this system exists
The 20 ft CubeDC carries eight to twelve racks and up to 300 kW of IT load in a standard ISO frame. Because it is built and tested in the factory, the site work is reduced to a foundation, a power connection and a network link — which is often the difference between a project that starts this quarter and one that starts next year.
The enclosure is insulated and weatherproofed for -25 °C to 50 °C ambient, with a hot-aisle return, N+1 in-row cooling and a clean-agent suppression system. Two units can be linked side by side to form a larger hall without changing the design.
Engineering
Key features
Every item below is verifiable in the datasheet or on the factory acceptance test record.
Data
Specifications
Typical values for the standard configuration. Site-specific schedules are issued with the quotation.
| IT load | Up to 300 kW |
|---|---|
| Racks | 8 – 12 × 42U |
| Dimensions | 6 058 × 2 438 × 2 896 mm (ISO 20 ft) |
|---|---|
| Insulation | 75 mm PIR panels, U-value 0.022 W/m²K |
| Protection | IP55, C5-M corrosion option |
| Type | In-row DX, N+1, free cooling option |
|---|
| UPS | 150–400 kVA modular |
|---|
| Fire | VESDA + clean agent suppression |
|---|
| Ambient range | -25 °C to 50 °C |
|---|
| Lead time | 6–8 weeks ex-works |
|---|
Deployment
Typical applications
Not on the list? These systems are also deployed in broadcast, rail signalling, laboratory and defence facilities — send us your environment and we will confirm suitability.
Documentation
Datasheets & manuals
The technical datasheet, installation manual and declaration of conformity for this product line are available in the download library. Drawings in DWG and PDF are issued with the quotation.
Related systems
Often specified together
HatchPower HP33 Modular UPS
A hot-swappable modular UPS platform that grows in 50 kVA steps, keeps critical loads on double conversion at 97.6% efficiency and allows zero-downtime maintenance from the front of the cabinet.
HatchPower HP11 Tower UPS
A compact tower UPS for small server rooms, branch offices and telecom cabinets. Online double conversion in a 2U–4U footprint with a maintenance bypass built in.
HatchPower HP33-L Lithium UPS
The HP33 platform paired with LFP battery cabinets and an integrated BMS. Same 97.6% efficiency, but a footprint and weight that fit a retrofit where lead-acid never could.
Next step
Get this system sized for your site.
Share your rack count, density and redundancy target. We reply with a configuration, drawings and a budgetary price.
