MicroCube MD Modular Data Center

A room-sized data center, delivered as one engineered pod.

A row of 4 to 12 racks with in-row cooling, modular UPS and containment, delivered as a pre-engineered pod and commissioned in two weeks.

250 kW Max. IT load
12 Racks per pod
2 weeks To live load
1.3 Design PUE
MicroCube MD Modular Data Center — 4–12 rack pre-integrated pod for 50–250 kW halls

Overview

Why this system exists

The MD pod is the middle ground between a single cabinet and a container: four to twelve racks, in-row cooling, a modular UPS frame, busway power distribution and end-of-row containment — all designed together, built in the factory, and delivered on a single power and network interface.

Because the pod is pre-engineered, the civil works on site are limited to a slab, a power feed and a cable entry. Typical deployment is two weeks from delivery to live load, and the pod can be expanded by adding racks to the row without redesigning the cooling or power distribution.

Positioning. 4–12 rack pre-integrated pod for 50–250 kW halls. Configurations are built to order — capacity, redundancy, enclosure rating and monitoring can be specified for your site.

Engineering

Key features

Every item below is verifiable in the datasheet or on the factory acceptance test record.

4–12 racks, 50–250 kW IT capacity
In-row cooling with N+1 units
Modular UPS and overhead busway
End-of-row containment included
DCIM with per-rack power and temperature
Two-week site commissioning

Data

Specifications

Typical values for the standard configuration. Site-specific schedules are issued with the quotation.

Capacity specifications
IT load50 – 250 kW
Racks4 – 12 × 42U

Deployment

Typical applications

Enterprise secondary sites University and research HPC rooms Hospital and imaging departments Manufacturing plants with OT/IT convergence

Not on the list? These systems are also deployed in broadcast, rail signalling, laboratory and defence facilities — send us your environment and we will confirm suitability.